BIOL. Technical characteristics
TECHNICAL DATA
The electronic unit |
Technical characteristics |
Input voltage of the network |
100-240 VAC 0.35-0.2 A |
Network frequency |
50/60 Hz |
Output voltage |
12-15V |
Output current (A) |
5A |
Output power (W) |
60W |
LADDA AA Battery rechargeable |
2450 mA/h Battery Cell Composition NiMH |
Telescopic antenna |
Frequency range 40 MHz-6 GHz Diameter of the thickest section: 5.2 mm Total length folded: 95 mm Total length unfolded: 290 mm (5 sections unfolded) Connector: SMA-male (pin). |
Electricity consumption |
max. 15V.A |
Total output power |
0.1 W |
The ambient temperature during the operation process |
5 – 40 °C |
The ambient temperature during a storage and transportation |
-25 ° C without relative humidity control + 70 ° C with relative humidity control This class 7K3 as described in IEC/TR 60721-4-7:2001 |
Ambient air pressure |
700-1060 hectopascal |
Air humidity |
15%-93%, without condensation |
Total weight |
2,0 kg. |
Net weight |
0,5 kg. |
Dimensions of the device BIOL (D / W / H) |
191x126х25 mm. |
Protection against water penetration |
IP20 |
Software version |
V.1.02 |
The device power supply unit is a means of simultaneous electrical separation of the BIOL device power supply circuits from the mains power supply circuits.
The temperature of all surfaces of the medical device does not exceed 40 ± 0.5°C
As the BIOL has a battery for wireless mode of operation, the following technical features shall be considered:
Typical Application Features |
NiMH vs. Lithium Primary |
NiMH vs. Alkaline |
Rated Voltage |
1.25V vs. 1.5V |
1.25V vs. 1.5V |
Discharge Capacity |
NiMH will not last as long as primary lithium (single cycle) |
NiMH lasts longer in high drain, less in light drain devices than alkaline |
Recharge Capability |
Several hundred cycles for NiMH, N/A for lithium primary |
Several hundred cycles for Ni-MH, N/A for alkaline primary |
Discharge Voltage Profile |
Both relatively flat discharge |
NiMH is flat vs. sloped for alkaline |
Self-Discharge Rate |
NiMH retains 50-80% @ 12 months Lithium retains >90% @ 15 years |
NiMH retains 50-80% @ 12 months Alkaline retains 80% @ 10 years |
Low Temperature Performance |
Lithium better than NiMH |
NiMH better than alkaline |
Battery Weight |
Lithium is lighter |
Alkaline is lighter |
Environmental Issues |
Recycling options available for NiMH and lithium |
Recycling options available for NiMH and some alkaline |
|
The battery is replaced by yourself. We will take no responsibility for any accident when the cell is used under other conditions than those described in this Document. We will inform, in a written form, the customer of improvement(s) regarding the proper use and handling of the cell, if it is deemed necessary. |
|
Batteries have their own life cycles. If the time of working of the BIOL in wireless mode becomes much shorter than usual, the battery cell life is at an end. Please ask your distributor/manufacturer for replacement. |
|
In case the battery is damaged, and the fluid leak is detected, avoid the contact with it. If it liquid leaks onto your skin or clothes, wash thoroughly with fresh water immediately. If liquid leaking from the battery gets into your eyes, do not rub your eyes. Wash them thoroughly with clean edible oil and visit a medical professional immediately. |
|
Strictly prohibits to use the MD BIOL close to fire or inside of a car where the temperature can reach 60°C and more. Also, do not charge/discharge it in such conditions (it may cause an explosion of the battery cell). |
|
Replacing the battery with insufficiently trained personnel can lead to danger! (temperature rise, fire, explosion). It is forbidden to replace the battery on its own. |
|
A specific condition of storage related to the Ni-MH battery. During a long period of storage, cells should be maintained every 90 days (to keep the lifetime of the cell): the standard method of the charge-discharge cycle should be applied. Do not store the MD BIOL in wet or cold conditions! Moisture and cold increase the discharge rate of the battery. And under the influence of extremely high temperatures, there is a risk of explosion of the battery. |
Minimum requirements to a computer, both for hardware and software, which are enough to use with PWA BIOL
Minimum hardware requirements |
Minimum software requirements |
|
HDD/SSD |
min. 128 Gb (256Gb is preferable) |
Operating system |
RAM |
min. 4 Gb and more |
Windows 10 and higher, macOS 10.13 and higher. Edge 79 and above. Chrome version 56 and above. Vivaldi version 5.3 and above. For the iOS operating system, you can use the Bluefly web browser version 3.9.1 or higher. |
Display |
min. 5” -55” and more definition HD, FHD, QHD or more |
|
Bluetooth |
BLE |
|
Medical grade computer (or mobile gadget) is recommended for use in combination with the MD BIOL. In any case, the local regulations and requirements regarding computers (or mobile gadget) in medical care institutions must be followed by the user. |
Any anti-virus software, if installed by the user, must be configured in such a way that the PWA BIOL software is not blocked. |